| STEP | Test Phase Definition | Temp °C (°F) | Relative Humidity | Supp. Cooling Air °C (°F) | Supp. Cooling Mass Flow (lbs/min) | Altitude | Test Item- Operating/non op. | Func Test | Duration |
|---|---|---|---|---|---|---|---|---|---|
| 19 | Hot/Dry High Altitude Functional test | Max Op Temp | <10% | Per Spec | Mass Flow adjusted for Alt | Max Op Alt | Operating | Yes | 15 minutes minimum |
| 20 | Ramp to Loiter/Cruise Temp | Ramp (Max Op Temp to Cruise Op Temp) (Note 6) | <10% | Per Spec | Mass Flow adjusted for Alt | Max Op Alt | Operating | No | 45 minutes minimum |
| 21 | Loiter/Cruise Altitude Ramp | Cruise Op Temp (Note 6) | <10% | Per Spec | Ramp (Adjust Mass Flow for Cruise Alt) | Ramp to Cruise Alt (Note 5) | Operating | No | As Required |
| 22 | Hot/Dry Loiter/Cruise Soak | Cruise Op Temp | <10% | Per Spec | Mass Flow adjusted for Cruise Alt | Cruise Alt (Note 7) | Operating | No | 3 hours minimum |
| 23 | Hot/Dry Loiter/Cruise Functional test | Cruise Op Temp | <10% | Per Spec | Mass Flow adjusted for Cruise Alt | Cruise Alt (Note 7) | Operating | Yes | As Required |
| 24 | Ramp to Site Ambient | Ramp to ambient (Note 2) | <10% | Per Spec | Per Spec | Ramp to Site (Note 5) | Operating/Non-Operating | No | As Required |
| 25 | Repeat Steps 2 thru 24 as required |
2. PDF page 771
| STEP | Test Phase Definition | Temp °C (°F) | Relative Humidity | Supp. Cooling Air °C (°F) | Supp. Cooling Mass Flow (lbs/min) | Altitude | Test Item- Operating/non op. | Func Test | Duration |
|---|---|---|---|---|---|---|---|---|---|
| 26 | Post Functional Test | Standard Ambient | Uncontrolled | Off | OFF | Site | Operating/Non- operating | Yes | Minimum Time required Post Test and power down |