2.5
kHz) will be suitable. For spectral computations, a maximum 5 Hz analysis filter bandwidth is recommended.
-
(8) Analysis procedures will be in accordance with those requirements and guidelines provided in paragraph 6.1, reference a. In particular, the test item response acceleration time histories will be qualified according to the procedures in paragraph 6.1, reference b. In severe cases of response acceleration, it may be necessary that each time history be integrated to detect any anomalies in the measurement system, e.g., cable breakage, amplifier slew-rate exceedance, data clipped, unexplained accelerometer offset, etc. The integrated amplitude time histories will be compared against criteria given in paragraph 6.1, reference b.
-
c. Tailoring. Necessary variations in the basic test procedures to accommodate LCEP requirements.