Bolted flange plate connections are prequalified for use in special moment frame (SMF) and intermediate moment frame (IMF) systems within the limitations of these provisions.

Figure description:
Bolted Flange Plate Moment Connection (Fig. 7.1
Key Components:
- Column: Features continuity and doubler plates as required.
- Beam: Connected to the column flange using top and bottom flange plates and a web connection.
- Flange Plates: Bolted to the beam flanges; may include shims if required.
- Single-plate Web Connection: Bolted connection between the beam web and the column.
Dimensional Parameters:
- Protected Zone: Defined as .
- : Distance from the column face to the furthest bolt row on the flange plate.
- : Distance from the column face to the first bolt row on the flange plate.
- : Spacing between individual bolt rows.
Fig. 7.1. Bolted flange plate moment connection.
Exception: Bolted flange plate connections in SMF systems with concrete structural slabs are only prequalified if the concrete slab is isolated in accordance with Section 2.3.4.