H7.1 Scope
Composite plate shear walls—concrete filled (C-PSW/CF) shall be designed in conformance with this section. This section is applicable to C-PSW/CF consisting of planar, C-shaped, or I-shaped walls, where each wall element consists of two planar steel plates with concrete infill between them. Composite action between the plates and concrete infill is achieved using either tie bars or combination of tie bars and steel headed stud anchors.
In each wall element, the two steel plates shall be of equal nominal thickness and connected using tie bars. The steel plates shall comprise at least 1%, but no more than 10% of the gross wall area.
Boundary elements or flange or closure plates shall be used at the open ends of the wall elements. The boundary elements shall be either (a) half-circular section of diameter equal to the distance between the two web plates or (b) circular filled composite members.
The height-to-length ratio, , of the composite walls shall be greater than or equal to 3.
H7.2 Basis of Design
C-PSW/CF, designed in accordance with these provisions, are expected to provide significant inelastic deformation capacity through developing the plastic moment strength of the composite C-PSW/CF cross section, by yielding of the steel plates and the concrete attaining its compressive strength. The cross section shall be detailed such that it is able to attain its plastic moment strength. Shear yielding of the steel web plates shall not be the governing mechanism.
H7.3 Analysis
The effective stiffness of composite walls shall be calculated in accordance with Specification Section I1.5.
H7.4 System Requirements for C-PSW/CF with Half-Circular or Circular Boundary Elements
H7.4a Steel Web Plate of C-PSW/CF with Half-Circular or Circular Boundary Elements
The maximum spacing of tie bars in vertical and horizontal directions, , shall be as follows:
(H7-1)
where
of elasticity of steel
= 29,000 ksi (200 000 MPa)
specified minimum yield stress, ksi (MPa)
= thickness of plate, in. (mm)
When tie bars are welded to the steel plates, the thickness of the plate shall develop the tensile strength of the tie bars.
H7.4b Half-Circular or Circular Boundary Elements
The diameter-to-thickness ratio, , for the circular part of the C-PSW/CF cross section shall be limited as follows:
(H7-2)
where
outside diameter of round hollow structural section (HSS), in. (mm)
design wall thickness thickness of HSS, in. (mm)
H7.4c Tie Bars
Tie bars shall be designed to resist the tension force, , while remaining elastic for all applicable load combinations, determined as follows:
(H7-3)
is the tension force resulting from the locally buckled web plates developing plastic hinges on horizontal yield lines along the tie bars and at mid-vertical distance between tie-bars and is determined as follows:
(H7-4)
where
is the tension force that develops to prevent splitting of the concrete element on a plane parallel to the steel plate.
(H7-5)
where
H7.5 System Requirements for C-PSW/CF with Flange or Closure Plates
H7.5a Steel Web and Flange Plates
In regions of flexural yielding (at the base), the steel plate slenderness ratio, , shall be limited as follows:
(H7-6)
where
- of elasticity of plate
= 29,000 ksi (200 000 MPa)
- thickness of plate, in. (mm)
H7.5b Tie Bars
The maximum spacing of tie bars shall be limited as follows:
(H7-7)
,
E
(H7-7M)
(H7-8)
where
diameter of tie bar, in. (mm)
H7.6 Members
H7.6a Flexural Strength
The available plastic moment strength of the C-PSW/CF shall be determined in accordance with Specification Section I1.2a.
H7.6b Shear Strength
The available shear strength of C-PSW/CF shall be determined in accordance with Specification Section I4.4.
H7.7 Connection Requirements
H7.7a Connection Between Tie Bars and Steel Plates
Connection of the tie bars to the steel plate shall be able to develop the full tension strength of the tie bar.
H7.7b Connection Between C-PSW/CF Steel Components
Welds between the steel web plates and the boundary elements or flange or closure plates shall be compete-joint-penetration groove welds.
H7.7c C-PSW/CF and Foundation Connection
Where the composite walls are connected directly to the foundation at the point of maximum moment in the walls, the composite wall-to-foundation connections shall be detailed such that the connection is able to transfer the base shear force and the axial force acting together with the overturning moment, corresponding to 1.1 times the plastic composite flexural strength of the wall. The plastic composite flexural strength of the wall shall be obtained by the plastic stress distribution method described in Specification Section I1.2a. Applicable and factors shall be used for different elements of the cross section while establishing section force equilibrium and calculating the flexural strength.
H7.8 Protected Zones
The regions subjected to inelastic straining at the base of the composite walls shall be designated as protected zones.
H7.8a Splices
Steel plate and boundary element splices located in the designated protected zones shall develop the full strength of the weaker of the two connected elements.
H7.9 Demand Critical Welds in Connections
Where located within the protected zones, the following welds shall be demand critical and shall satisfy the applicable requirements:
-
(a) Welds connecting the composite wall web plates to the boundary elements or to the flange or closure plates
-
(b) Welds in the composite wall steel plate splices
-
(c) Welds at composite wall steel plate-to-base plate connections