Chapter F includes the following major changes and additions in this edition of the Provisions:
-
(1) Ordinary concentrically braced frames above seismic isolation systems have been removed from the Provisions.
-
(2) The Provisions for special concentrically braced frame (SCBF) beams in V- and inverted V-braced frames are revised to permit some limited yielding.
-
(3) For SCBF, exceptions are added for conditions when braces need not meet the require- ments for lateral force distribution.
-
(4) Columns in buckling-restrained braced frames (BRBF) are revised to satisfy the require- ments of Section D1.1 for highly ductile members.
-
(5) Provisions for overall stability of BRBF and connection assemblies are included.
-