The force ratio is defined as the ratio of external load to the induced load increment seen by the fastener, and is given by,
For certain joint configurations (such as joint type 2 in Figure 5-1) the external load's effective point of action is at the outer surface of the flanges. This is the situation that is shown in Figure 7-5. For such joints, the force ratio can be shown to depend on the relative stiffnesses (or compliances) of the fastener and the clamped parts,
where & are the respective stiffnesses of the fastener and clamped parts, and & are the respective compliances of the fastener and clamped parts.
From Figure 7-6 it can be seen that,
therefore, using Equation [7.4.2],
Rearranging, the load reduction felt by the clamped parts due to the external load is given by,
Equations [7.4.2], [7.4.3], [7.4.4] and [7.4.5] are only valid for joints where the point of application of the external load is the outer surface of the flanges. In general, the external load is effectively applied at points located within the flanges. Therefore, the loading plane factor, n, is introduced into equation [7.4.2] resulting in,
Methods are presented in the following Sections for calculating the various parameters in Equation [7.4.6].