G6Doubly symmetric and singly symmetric members subjected to minor-axis shear
AISC 360-22, Specification for Structural Steel Buildings
Last Updated 29 Oct 2026
Hover any section to copy its link or text, ask Copilot about it, or bookmark it.
For doubly and singly symmetric members loaded in the minor axis without torsion, the nominal shear strength, Vn, for each shear resisting element is
Vn=0.6FybftfCv2
(G6-1)
where
Cv2= web shear buckling strength coefficient, as defined in Section G2.2 with h/tw=bf/2tf for I -shaped members and tees, or h/tw=bf/tf for channels, and kv=1.2
bf= width of flange, in. (mm)
tf = thickness of flange, in. (mm)
User Note: Cv2=1.0 for all ASTM A6/A6M W, S, M, and HP shapes, when Fy≤70ksi(485MPa).